WINSMART™ LY36 SMART EXPLOSION PROOF DIFFERENTIAL PRESSURE TRANSMITTER

WINSMART™ LY36 SMART EXPLOSION PROOF DIFFERENTIAL PRESSURE TRANSMITTER

WINSMART™ LY36 SMART EXPLOSION PROOF DIFFERENTIAL PRESSURE TRANSMITTER

CRN
  • Monosilicone-based high performing transmitter
  • Explosion proof smart differential pressure transmitter for hazardous locations
  • Sour gas NACE0175 compliant
  • Built-in temperature sensor
  • 0.075% or 0.05% accuracy
  • Simple to operate 3-push button control
  • HART 5 or Modbus communications available
  • Low power option available
  • Re-zero function for safe field calibration
  • 20:1 turndown allows for installation in any application setting
  • CRN Registered
  • 5 year Warranty
Differential pressure monitoring for oil and gas installations, well head process control, petrochemical installations, power generation equipment and all hazardous locations
Parameter Specification
Output Signal 4/20 mA, 2-wire / V = 10.5-55 Vdc
4/20 mA + HART 5, 2-wire / V = 16.5-55 vdc or 12.55-55 Vdc (low power)
1/5 Vdc, 3-wire / V = 10.5-55 Vdc
Modbus, 4-wire / V = 9-30 Vdc
LCD >Display Available with LCD display (standard) or without LCD display (optional)
Accuracy 0.075% URL standard, 0.05% optional
Stability 0.2% per 5 years
Temperature Range Working: -40/85°C (with display -20/70°C), -40/185°F (without display -4/158°F)
Storage: -40/110°C (with display -40/85°C), -40/230°F (without display -40/185°F)
Media: silicone oil filling: -40/120°C (-40/248°F)
Working Humidity 5-100% at 40°C (104°F)
Pressure Connection 1/4” or 1/2” NPTM or F, 1/4” or 1/2” GM (large 12mm orifice)
Housing Rugged die-cast aluminum housing, painted blue
Wetted Parts 316L SS with PTFE o-ring (Hastelloy® C optional)
Overload Pressure Maximum of 3,600 or 6,000 psi
Power Consumption =500 mW @ 24 VDC, 20.8 mA (LCD); </=493mW @ 24VDC, 20.55mA (without LCD)
Wake Up time 6 seconds
Vibration 20g, 20Hz…5kHz
According to GB/T 1827.3 / IEC 61298-3 tests, <0.1% URL
Shock 20g, 20Hz…5kHz
Available Pressure Units kPa, Mpa, bar, psi, mmHg, mmH2O, mH2O, inH2O, ftH2O, inHg, mHg, TORR, mbar, g/cm2, kg/cm2, Pa, ATM
Available Temperature Units Celsius, Fahrenheit
Protection Class EMI, ESD, RFI, reverse polarity protected; Surge protection IEC1000-4-5
Approvals CSA, for USA & Canada
• Class I, Division 1, Group A,B,C and D T6 | Class II, Division 1 Group E,F and G T80oC  | Class III
Intertek, for USA & Canada
• Class I, Zone 0 A Ex ia IIC T6 Gb | Class I, Division 1, Group A-D, T6 | - 40oC to 60oC
SIL 2 Capable
• IEC 61508: 2010
ATEX
• II 2G Ex db IIC T6 Gb
• II 1G Ex ia IIC T6 Ga
Protection Class IP66 / IP67
Weight 8.8 lbs (4.0 kg)
Operational Life 100 million cycles

Support tools

Configurator

Catalogues & Brochures

Pressure & Temperature Converter

distributor locator

request a quote

ask us your questions

Cookies

This website uses cookies to ensure you get the best experience on our website.