WINSMART™ LY36 SMART EXPLOSION PROOF DIFFERENTIAL PRESSURE TRANSMITTER
WINSMART™ LY36 SMART EXPLOSION PROOF DIFFERENTIAL PRESSURE TRANSMITTER
DESCRIPTION & FEATURES
- Monosilicone-based high performing transmitter
- Explosion-proof smart differential pressure transmitter for hazardous locations
- Sour gas NACE0175 compliant
- Built-in temperature sensor
- 0.075% or 0.05% accuracy
- Simple to operate 3-push button control
- HART® or Modbus communications are available
- Low power option available
- Re-zero function for safe field calibration
- 10:1 rangeability allows for installation in any application
- CRN Registered
- 5-year warranty
- Differential pressure transmitters are useful instruments for measuring the difference between two pressures. If you’re looking for a differential pressure transmitter, look no further! Our LY36 smart differential pressure transmitter is one of the top-performing differential pressure transmitters in the market.
Applications
Differential pressure monitoring for oil and gas installations, well head process control, petrochemical installations, power generation equipment and all hazardous locations
SPECIFICATIONS
DOCUMENTS
DRAWINGS
FAQS
Parameter | Specification |
---|---|
Output Signal |
4/20 mA, 2-wire / V = 10.5-55 Vdc 4/20 mA + HART, 2-wire / V = 12-55 Vdc (low power) 1/5 Vdc, 3-wire / V = 10.5-55 Vdc Modbus, 4-wire / V = 9-30 Vdc |
LCD >Display | Available with LCD display (standard) or without LCD display (optional) |
Accuracy | 0.075% URL standard, 0.05% optional |
Stability | 0.2% per 5 years |
Temperature Range |
Working: -40/85°C (with display -20/70°C), -40/185°F (without display
-4/158°F) Storage: -40/110°C (with display -40/85°C), -40/230°F (without display -40/185°F) Media: silicone oil filling: -40/120°C (-40/248°F) |
Working Humidity | 5-100% at 40°C (104°F) |
Pressure Connection | 1/4” or 1/2” NPTM or F, 1/4” or 1/2” GM (large 12mm orifice) |
Housing | Rugged die-cast aluminum housing, painted blue |
Wetted Parts | 316L SS with PTFE o-ring (Hastelloy® C optional) |
Overload Pressure | Maximum of 3,600 or 6,000 psi |
Power Consumption | =500 mW @ 24 VDC, 20.8 mA (LCD); </=493mW @ 24VDC, 20.55mA (without LCD) |
Wake Up time | 6 seconds |
Vibration |
20g, 20Hz…5kHz According to GB/T 1827.3 / IEC 61298-3 tests, <0.1% URL |
Shock | 20g, 20Hz…5kHz |
Available Pressure Units | kPa, Mpa, bar, psi, mmHg, mmH2O, mH2O, inH2O, ftH2O, inHg, mHg, TORR, mbar, g/cm2, kg/cm2, Pa, ATM |
Available Temperature Units | Celsius, Fahrenheit |
Protection Class | EMI, ESD, RFI, reverse polarity protected; Surge protection IEC1000-4-5 |
Approvals |
CSA, for USA & Canada • Class I, Division 1, Group A,B,C and D T6 | Class II, Division 1 Group E,F and G T80oC | Class III Intertek, for USA & Canada • Class I, Zone 0 A Ex ia IIC T6 Gb | Class I, Division 1, Group A-D, T6 | - 40oC to 60oC SIL 2 Capable • IEC 61508: 2010 ATEX • II 2G Ex db IIC T6 Gb • II 1G Ex ia IIC T6 Ga |
Protection Class | IP66 / IP67 |
Weight | 8.8 lbs (4.0 kg) |
Operational Life | 100 million cycles |